REF. CONTROL/INDICATOR FUNCTION
1 LOCAL/REMOTE, switch Selects LOCAL or REMOTE control of the transmitter. (Remote monitoring is operational
in either the LOCAL or REMOTE switch position.)
2 LOCAL, status indicator Indicates that the remote control inputs to the transmitter are disabled, and only local con-
trol is possible.
3 REMOTE, status indicator Indicates that the transmitter remote control inputs are active. (The transmitter may still be
controlled with the panel pushbuttons as well.)
4 AUDIO INPUT board, -15V
supply status indicator.
Bicolor LED indicator. Indicates status of -15 Volt supply on the audio input board.
GREEN indicates normal operation; RED indicates -15 Volt supply fault.
5 AUDIO INPUT board, +15 V
supply status indicator.
Bicolor LED indicator. Indicates status of +15 Volt supply on the audio input board.
GREEN indicates normal operation; RED indicates +15 Volt supply fault.
6 OSCILLATOR, RF output
status indicator
Bicolor LED indicator. Indicates oscillator board RF output status. GREEN indicates nor-
mal RF output; RED indicates low or no RF output. (Note 1)
7 BUFFER AMP, RF output status
indicator
Bicolor LED indicator. Indicates buffer amplifier RF output status. GREEN indicates nor-
mal RF output; RED indicates low or no RF output. (Note 1)
8 PREDRIVER, RF output status
indicator
Bicolor LED indicator. Indicates predriver RF output status. GREEN indicates normal RF
output; RED indicates low or no RF output. (Note 1)
9 RF AMP, indicator Bicolor LED indicator. Red indicates a failure of an RF Amplifier. Green indicates a nor-
mal, no fault condition. (Note 2)
Table 3A-3. ColorStat™ Panel
Controls & Indicators
Figure 3A-3. ColorStat™ Panel
Controls & Indicators
Section IIIA - Controls and Indicators
Rev AA: 8/9/2000 888-2297-002 3A-3
WARNING: Disconnect primary power prior to servicing.