Figure 5-10
Oscillator sync samples at Oscillator A17TP4 and TP5. Trans-
mitter operating at 25 kW with no modulation. The two sam-
ples are in phase.
Figure 5-11
Demodulated audio. Transmitter operating at 5 kW with 100
Hz, approximately 10% triangle modulation
Top Trace - Demodulated Audio
Bottom Trace - Modulation Encoder waveform of Step 6. Good
binary alignment shown.
Figure 5-12
Demodulated audio. Transmitter operaeting at 5kW with 100
Hz, approximately 10% triangle modulation.
Top Trace - Demodulated audio.
Bottom Trace - Modulation Encoder waveform of Step 6. Insuf-
ficient 1/2 Binary Step output shown.
Section V - Maintenance
Rev. Z1: 06-02-00 Additional info to ECN 46105 888-2297-002 5-23
WARNING: Disconnect primary power prior to servicing.