4-2
RF-7800W
TROUBLESHOOTING AND MAINTENANCE
The Telnet session must connect to the RF-7800W HCLOS
Radio within approximately 20 seconds from when the radio
starts responding to pings. Logging into the default IP Address
will cause the unit to be reset to the factory default
configuration.
i. Enter the following to log in:
1. User Name - type admin and press [Enter].
2. Password - type admin and press [Enter]. The password characters do not echo to the computer
screen.
j. Enter the command save defaultconfig and press [Enter] to ensure that all parameters are set to default
values.
k. Enter the following commands to set a new IP address. A 192.168.26.2# prompt is shown at each step.
1. set ipaddr <IP Address> followed by [Enter].
Note the spaces in this example: set ipaddr 192.168.100.1
2. save config followed by [Enter]. The message, “Connection to host lost.” will display.
l. Select the user command to enter new user name and password information, if required.
Figure 4-1. Factory Default Reset Time Frame
CL-0426-4200-0020
POWER OFF
8 TO 10
SECONDS
POWER ON
GREATER THAN
2.5 MINUTES
POWER ON APPROX.
2 MINUTES 40 SECONDS