5-34 888-2595-001 12/20/11
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
ZX Series
Verify push-on (faston) DC connectors make snug contact upon connection.
Remove connector and gently press closed with pliers if connection is loose.
Note three fuses for AC MAINS LOW alarm(s). It may not be necessary to
remove entire board if only fuse is blown (false AC MAINS LOW alarm).
5.5.8 RF Output Assembly (971-0023-026/027/028)
The entire output assembly lifts out of transmitter and can be replaced as a complete
“module” at the users discretion. A procedure is provided below. To facilitate
assembly removal and insertion, it is possible to first remove the user interface sub-
panel and support brace on the transmitter rear panel to increase the size of the access
hole. However, this is not strictly required, as the output assembly can still be installed
without removing these items.
Certain aspects of the output assembly can be serviced in the field, notably the
combiner cables and ballast loads. Damaged ballast loads and cables are usually
evident from visual inspection. If cables are replaced, make sure that cables are
replaced with the exact same type (RG-142 and RG-302). Do not use RG-58, RG-59,
RG-223 cable under any circumstances.