Standard crank handle:
This handle can be replaced at any time
by one with kick-back damping if this
becomes necessary or is required by
regulations.
Attention !
There is a risk of injury if the shaft of the
crank handle or its tubular handgrip are
worn.
Preparations:
Demontage:
Inspection / repair:
– Visual inspection.
– Inspect shaft 1 and tubular handgrip 2
for wear or breakage.
Note:
If the shaft of the crank handle is worn,
always renew the complete handle.
The tubular handgrip can be renewed
separately if necessary.