2L41C, 2M41, 2M41Z Operation and use
HATZ
43Operator’s Manual
Step Activity
4 As soon as the engine is running, release the starting key.
The starting key springs back to position "I" and remains in
this position during operation.
The charge control (2) and oil pressure display (3) go out.
The operating display (1) lights up.
NOTICE
i
In case of irregularities, switch off the engine immediately.
Identify the fault and eliminate it.
For details of troubleshooting, see chapter 9.1 Trou-
bleshooting, page 84.
Electrical automatic shutoff (additional equipment)
The identifying feature of the electrical automatic shutoff is brief flashing of
all indicators after the starting key is turned to position "I".
NOTICE
i
If the engine stops again immediately after starting, or stops
independently during operation, this is an indication that a
monitoring element of the automatic shutoff has been acti-
vated.
Remedy the fault before further starting attempts (see the
chapter 9.1 Troubleshooting, page 84).
Despite the automatic shutoff, check the oil level every 8-15
operating hours (see the chapter 7.8 Checking the oil level
and adding oil if necessary, page 47).
If the engine switches off due to an electrical fault signal or
due to insufficient oil pressure with the aid of the automatic
switch-off, an emergency start can be attempted by the
user. The user must bear responsibility for any resulting
damage (see the chapter 9.2 Emergency start, page 89).