74 4001001030 E 06.20 USA / GB
D- Operation instructions
Compact 8 (C 2032E) - Compact 8W (C 2047E) - Compact 10 (C 2747E) - Compact 10N (C 2632E) -
Compact 10N-1 - Compact 12 (C 3347E) - Compact 14 (C 3947E)
1.2 - O
PERATION
FROM
THE
GROUND
CONTROL
BOX
Turning "ON" and "OFF" of the machine is performed with selector key switch (92).
Activation of a desired control box is achieved by turning the control box energizing selector
switch ( 92 ) to the desired position.
The ground control box is energized and is active ONLY when :
• The emergency stop on the ground control box is not pushed in.
• The machine is switched on.
• Ground control box is selected.
An E-stop button at each control box stops all movements when pressed in (deactivated).
N.B.-:-A
N E-STOP BUTTON PRESSED IN DOES NOT TURN OFF THE MAIN POWER SUPPLY TO THE
MACHINE
.
An Enable Switch ( 9 ) provided must be activated and maintained to authorize one or more
function movements. If Enable Switch ( 9 ) is kept engaged without selecting a function
movement for more than 8 s; Enable Switch is automatically de-activated.
The release of "Enable switch" ( 9 ) while performing a movement stops all the movements.
The stop of movements is progressive. If the Enable Switch system is re-pressed, the move-
ment doesn't restart. It could restart only when the selected function switch/joystick is re-
leased to neutral position.
All switches and joystick operating a movement, return automatically to neutral when
released.
The ground control box is designed for maintenance and emergency rescue operations only.
Refer to Section D 4.2 To rescue operator in platform.
The status of the switches is tested automatically when the machine is switched on, and
checked at every starting. A switch will be active only after it has been detected to be in neu-
tral position. The following switches are not controlled :
• Beacon light (if fitted)
A buzzer beeps in the following conditions :
Overload (if fitted).
Machine out of stowed position and on a slope greater than allowable slope.
• Movements option.
Indicators : All indicators are checked after powering on the machine