These lights illuminated together indicate Low or No water flow through cell vessel
Verify pump is on and water is flowing. If pump is
running, remove power to the AQR100 for two mins
then re-apply. If error still does not clear go to step 2B.
Verify Pump is Turned On and Running
Problem Detected: Inadequate Flow
Step 2A
Verify the timer and
breaker are in the“ON”
position
The cleanliness of the cell plays a major role in the AquaRite 100’s ability to report salt levels
accurately.
Inspect the Cell
Step 2B
Remove
calcium and
other debris
from the cell
The cell must be clean to report an accurate salt reading.
If cell is dirty, clean the cell (steps on pg.11-12). If cell is
clean, like the image above, go to step2C.
33