Problem Detected: LED #8
Inspect cell vessel and verify cell plates are fullycovered
by moving water. Clear cell of any obstructions.
If problem persists, go to step 6D.
Verify Moving Water Fully Covers Cell Plates
Step 6C
These lights illuminated together indicate there is no current to the Cell.
*Cell cord must be connected securely and be free of
damage, replace if necessary (GLXAQR100CABLE). **If
error does not clear replace the PCB (GLXAQR100PCB).
Verify cell cord is
securely
fastened to cell
Inspect cell cord
for damage or
corrosion
Step 6D
Inspect Cell Cord
*Follow the steps on pages 13-18 to access/test/replace cell cable
**Follow the steps on pages 23-27 to access/test/replace PCB