Do you have a question about the Heat & Glo SL-750TRS-IPI-E and is the answer not in the manual?
Fuel Type | Natural Gas or Liquid Propane |
---|---|
Ignition Type | IPI (Intermittent Pilot Ignition) |
Vent Type | Direct Vent |
Log Set Material | Ceramic Fiber |
Efficiency | 70% |
Warranty | Limited Lifetime |
Details the certification standards and laboratories for the appliance.
Provides a table of BTU input specifications for different models and gas types.
Explains adjustments for reduced input rates at higher elevations in USA and Canada.
Specifies adherence to local codes, NEC, and Canadian Electric Code for wiring.
Provides essential safety warnings for operating the gas fireplace, including hot glass.
Step-by-step guide for lighting the intermittent pilot ignition (IPI) system.
Detailed procedure for lighting the pilot on standing pilot models.
Lists annual maintenance tasks for homeowners, like glass cleaning and checking doors.
Outlines annual tasks for qualified technicians, including burner and ignition checks.
Key factors for designing and installing the direct vent gas appliance.
Lists necessary tools and building supplies for installation.
Guidance on choosing an appliance location considering clearances.
Specifies minimum air space clearances to combustibles for the appliance and vent pipe.
Details minimum clearances for mantels and wall projections above the appliance.
Information on approved Hearth & Home Technologies DVP or SLP venting systems.
Defines standards used for vertical and horizontal vent measurements.
Guidelines for maintaining air space between vent pipe and combustibles.
Instructions for framing holes and installing wall shield firestops.
Steps for assembling DVP vent sections to the firebox.
Instructions for attaching SLP vent components to appliance collars.
Procedure for assembling slip sections for vent pipe.
Details required gas pressures for Natural Gas and Propane.
Guidance on connecting the gas supply line to the appliance.
Instructions for adjusting appliance performance at high altitudes.
Specifies electrical wiring requirements and safety precautions.
Wiring instructions for the IntelliFire ignition system.
Wiring guidelines for the standing pilot ignition system.
Instructions for installing and removing the splatter guard.
Minimum vertical and horizontal dimensions for combustibles around the appliance.
Guidelines for applying facing and finishing materials.
Information on certified doors and finishing material thickness.
Instructions for removing packaging materials from the appliance.
Guidance on cleaning the appliance interior before use.
Instructions for correctly placing lava rock and ember material.
Steps for installing the refractory panels inside the firebox.
Troubleshooting guide for issues with the standing pilot ignition system.
Troubleshooting guide for issues with the IntelliFire ignition system.
Diagram showing actual appliance dimensions for reference.
Illustrations and specifications of various vent system components.
Listings of available service parts for different models.