Heat Controller DVC/DVH Inverter Mini-Split
15
7. Operating Conditions
Indoor (Room)
Temperature
Cool Mode Heat Mode Dry Mode
≥62°F(17°C) ≤86°F(30°C)
50°F(10°C)
Outdoor (Ambient)
Temperature
5°F - 122°F
(-15°C - 50°C)
5°F - 86°F
(-15°C - 30°C)
32°F - 122°F
(0°C - 50°C)
CAUTION:
1. If the unit is used outside of the above conditions, certain safety protection features may come into
operation and cause the unit to operate abnormally.
2. If the room relative humidity is greater than 80%, the surface of the indoor unit may attract
condensation. To lessen the chance for condensate dripping, set the vertical air flow louver to its maximum
angle (vertically to the floor) and set the fan mode to HIGH.