49
Heat Controller DVC/DVH Inverter Mini-Split
47
10.4: Pressure on Service Port
10.4.1 Cooling:
()
IDT
ODT
75
23.89
85
29.44
95
35
105
40.56
115
46.11
BAR 70/59 8.2 7.8 8.1 8.6 10.1
BAR 75/63 8.6 8.3 8.7 9.1 10.7
BAR 80/67 9.3 8.9 9.1 9.6 11.2
()
IDT
ODT
75
23.89
85
29.44
95
35
105
40.56
115
46.11
PSI 70/59 119 113 117 125 147
PSI 75/63 124 120 126 132 155
PSI 80/67 135 129 132 140 162
()
IDT
ODT
75
23.89
85
29.44
95
35
105
40.56
115
46.11
MPA 70/59 0.82 0.78 0.81 0.86 1.01
MPA 75/63 0.86 0.83 0.87 0.91 1.07
MPA 80/67 0.93 0.89 0.91 0.96 1.12
0.0
2.0
4.0
6.0
8.0
10.0
12.0
75 23.89 85 29.44 95 35 105 40.56 115 46.11
70/59
75/63
80/67