EasyManua.ls Logo

Heat Controller HEV Series - Page 29

Heat Controller HEV Series
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heat Controller HEV-HEH SEriES Design Guide
29
29
Heat Controller, LLC HEV/H SERIES Engineering Design Guide
Horizontal
Model
1Discharge Connection
Duct Flange Installed (+/- 0.20 in, +/- 5.1mm)
Return Connection
Standard Deluxe Filter Frame
(+/- 0.20 in, +/- 5.1mm)
MN
O
Supply
Height
P
Supply
Width
QR
S
Return
Width
T
Return
Height
UV
024 - 030
in
cm
2.6
6.6
4.8
12.2
11.9
30.2
11.9
30.2
2.6
6.6
4.8
12.2
22.6
57.4
15.8
40.1
0.8
2.0
1.0
2.5
036 - 042
in
cm
2.1
5.3
3.4
8.6
15.4
39.1
12.4
31.5
2.1
5.3
3.4
8.6
25.7
65.3
18
45.7
0.8
2.0
1.0
2.5
048 - 060
in
cm
2.5
6.3
1.5
3.8
18.2
46.2
15.9
40.4
2.5
6.3
1.5
3.8
36
91.4
18
45.7
0.8
2.0
1.0
2.5
1Discharge connection will change when using the accessory auxiliary electric heat package. Refer to the heater IOM for details.
Right Return Straight Discharge
Front
N
P
Blower
Outlet
M
O
Legend
CCP = Control/Compressor Access Panel (2’ min. clearance)
BSP = Blower Service Panel (2’ min. clearance)
ASP = Additional Service Panel (not required)
Right Return
Front
Straight
Discharge
5
ASP
Back
Discharge
Condensate
3 / 4” MPT
H
Front-View
4
3
2
1
A
CCP
BSP
Right Return Right View
- Filter Rack Knife Edge
Air Coil
C
V
U
B
ASP
T
S
Front
P
Blower
Outlet
M
O
Left Return Straight Discharge
Front
BSP
LEFT RETURN RIGHT RETURN
Air Coil
ASP
Front
Left Return Left View
- Filter Rack Knife Edge
1.1 [27.9mm]
C
V
T
SU
B
Right Return Back Discharge
A
Air Coil Side
C
R
P
Blower
Outlet
Q
O
ASP
ASP
BSP
Front
Left Return
H
ASP
BSP
BSP
Condensate
3 / 4” MPT
ASP
Air Coil Side
O
A
C
Left Return Back Discharge
P
Blower
Outlet
Q
R
BSP
N
G
F
D
E
3.25
[82.6mm] 3.25
[82.6mm]
1.6 [40.6mm]
K
L
J
1.6 [40.6mm]
Power Supply
3 / 4” [19.1mm] Knockout
1 / 2” [12.7mm]
Knockout
Low Voltage
1 / 2” [12.7mm]
Knockout
5
Straight
Discharge
Back
Discharge
Frame Depth
1 & 1 / 4" [31.8mm]
Flange Depth
3 / 4" [19.1mm]
Frame Depth
1 & 1 / 4" [31.8mm]
Flange Depth
3 / 4" [19.1mm]
CCP
CCP
CCP
CCP
ASP
Unit Hanger Detail
U
V
Front
W
Model U V W
024-030 48.4 [122.9] 24.6 [62.5] 20.3 [51.6]
036-042 53.3 [135.4] 24.6 [62.5] 20.3 [51.6]
048-060 68.0 [172.7] 27.6 [70.1] 23.3 [59.2]
Note: Provide 2’ minimum clear access to the Control/Compressor Access Panel and the Blower Service Panel.
HEH - Horizontal Dimensional Data

Related product manuals