Page
32
I
~
~
fUMf*!{*iil
CIRCUIT
DESCRIPTI
I
ON
I
Refer
to
the Schematic Diagram
(fold-out
from
Page
41)
while
you read
this
"Circuit
Description."
General Consideration
All
of
the
following
circuit
explanations refer
only
to
NPN
transistors
or
IN
channel F ET's. The descriptions ali
so
apply
equally
to
PNP
transistors and P channel
FET's
except
that
the
polarity
of
the
meter and
both
batteries
(B
1 and B2)
must
be
reversed.
Diode
D1
1
protects
the
meter
by
limiting
the voltage across
it
to
0.6 volts. Capacitors
C1
and
C2
prevent oscillations
from
occurring in
the
device being tested. Resistors R5 and
R6
limit
the
current
to
protect
controls
R
11
and R 12 in
case
a
short
circuit
occurs.
For
simplicity,
the
above components
are
110t
shown in
the
following
partial schematics.
All
switches are shown on
the
Schematic in the released
(out)
position
even
though
th
is
configuration
does
not
represent a
particular
test. This enables
you
to
easily trace a
particular test
circuit
by
pressing (mentally)
only
the
switch
related
to
that
test.
BATTERY
TEST
Each
battery
is
tested
separately.
The
NPN
position
of
the
NPN-PNP
switch
connects
battery
82
into
the
battery
0
RX~
TESTED
1 A
100 m A
10mA
l
rn
A
~
R8
i
R 1
~
R 2
~
RJ
~
R 4
.,
10
K Q
15Q
1 5
I)
~
lS
I)
~
166
I)
)
"1
+ -
+
82
1
5V
BETA==
testing
circuit.
The
PNP
position
of
the
NPN-PN
IP
switch
connects
battery
81
into
the
'battery
testing
circuit.
A
load,
simulating
operating
conditions,
is
connected
across
each
battery
while
the
battery
voltage
is
being
measured.
This
assures
that
the
battery
is
capable
of
supplying
adequate
current
and
voltage
for
the
tests.
62
R2
1.
Sv
1.SI)
1+
I
BAT
TEST
Figure 5
When
the
Bat Test switch
is
pressed, resistor
R2
is
placed
across
the
battery
terminals
to
load
the
battery.
See
Figure
5.
The
meter,
now
functioning
as
a
voltmeter,
measures
the
battery
voltage.
If
the
battery
is
serviceable (0.9
volt
or
more),
the
meter
pointer
will
fall
within
the
Bat
OK
mark
on
the
meter.
SET8
E
TA·c,a
R
11
IS K
I)
B 1
®
1. 5v
//~
82