Page 36
Heatilator • Constitution EPA Fireplace • 480-1091C
November 11, 2008
9.
There is very little room to pull the timer assembly out the
frontofthereplace.
P
lace your hand through the access
doorintheoorofthereplace.Letthetimerassembly
drop down and then rotate it up through the access door.
Figures 36.3 and 36.4.
7. Moveslidercontrolrodandlinkagearmtotherightand
out of the way. Pull rod down and out towards you. Lay
the control arm down. Figures 36.1 and 36.2.
8. Thetimerassemblyisboltedundertheface.Usea7/16
socket wrench to remove the 2 bolts. Figure 36.3.
Linkage Arm
Slider Control Rod
Linkage Arm
Slider Control Rod
Remove 2 bolts from timer assembly
Timer Assembly
with Gasket
REMOVE & REPLACE TIMER
1. Loosen set screw on timer, remove 2 screws and remove
timer. See Figure 36.5.
2. Install new timer using same 2 screws. It is very impor
-
tant that the D cut side of the timer shaft is facing the
opposite side of the linkage timer arm. Figure 36.6.
D cut side of timer shaft must face
away from the Linkage Timer Arm
Remove Timer
Loosen Set Screw
Remove
2 screws
Figure 36.1
Figure 36.2
Figure 36.3
Figure 36.4
Figure 36.5
Figure 36.6