17
441 01 2121 01
Table 5 – Air Delivery − CFM (with filter)*
Unit Size Operating Mode
CFM
Airflow
Setting
External
Static
Pressure
Range*
(In. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0701412 AIRFLOW (CFM)
†† Low Heat 735† 0−0.50 735 735 735 735 725
High Heat 1180† 0−1.0 1160 1165 1175 1180 1180 1180 1180 1180 1180 1175
†† 1−1/2−Ton Cooling 525 0−0.50‡ 515 500 500 490 485
†† 2−Ton A/C Cooling 700 0−0.50‡ 690 680 675 680 675
2−1/2−Ton A/C Cooling 875 0−1.0‡ 875 875 875 870 865 855 850 835 825 820
3−Ton A/C Cooling 1050 0−1.0‡ 1050 1050 1050 1050 1050 1050 1045 1035 1020 1000
3−1/2−Ton A/C Cooling 1225 0−1.0 1220 1225 1225 1225 1225 1220 1205 1190 1185 1170
Maximum 1400 0−1.0 1395 1400 1400 1400 1395 1385 1370 1340 1300 1245
0901716
Low Heat 985† 0−1.0 950 970 985 985 985 985 985 985 985 980
High Heat 1210† 0−1.0 1190 1205 1210 1210 1210 1210 1210 1210 1210 1200
†† 1−1/2−Ton A/C Cooling 525 0−0.50‡ 525 520 525 495 475
†† 2−Ton A/C Cooling 700 0−0.50‡ 680 680 680 675 670
2−1/2−Ton A/C Cooling 875 0−1.0‡ 815 845 845 855 850 850 845 835 820 805
3−Ton A/C Cooling 1050 0−1.0‡ 1005 1005 1015 1035 1040 1040 1035 1030 1025 1010
3−1/2−Ton A/C Cooling 1225 0−1.0 1190 1200 1200 1205 1205 1215 1205 1200 1185 1170
4−Ton A/C Cooling 1400 0−1.0 1350 1370 1390 1390 1400 1390 1380 1380 1360 1340
Maximum 1600 0−1.0 1595 1600 1600 1600 1595 1555 1505 1465 1430 1390
1102120***
Low Heat 1320† 0−1.0 1275 1295 1315 1320 1320 1320 1320 1320 1320 1315
High Heat 1475† 0−1.0 1460 1465 1475 1475 1475 1475 1475 1475 1465 1465
†† 2−Ton A/C Cooling 700 0−0.50‡ 700 700 700 700 700
†† 2−1/2−Ton A/C Cooling 875 0−0.50‡ 875 875 875 875 875
†† 3−Ton A/C Cooling 1050 0−0.50‡ 1050 1050 1050 1050 1050
3−1/2−Ton A/C Cooling 1225 0−1.0‡ 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225
4−Ton A/C Cooling 1400 0−1.0‡ 1400 1400 1400 1400 1400 1400 1400 1400 1400 1400
5−Ton A/C Cooling 1750 0−1.0‡ 1750 1750 1750 1750 1750 1750 1750 1750 1740 1725
6−Ton A/C Cooling 2100 0−1.0 2100 2100 2100 2100 2090 2075 2055 2040 2005 1970
Maximum 2200 0−1.0 2200 2190 2190 2180 2155 2145 2125 2100 2080 2020
1352422
Low Heat 1700† 0−1.0 1700 1700 1700 1700 1700 1695 1700 1695 1685 1670
High Heat 1915† 0−1.0 1900 1905 1915 1915 1915 1915 1915 1915 1915 1915
†† 2−Ton A/C Cooling 700 0−0.50‡ 700 700 700 700 665
†† 2−1/2−Ton A/C Cooling 875 0−0.50‡ 870 870 865 865 865
†† 3−Ton A/C Cooling 1050 0−0.50‡ 1010 1030 1050 1050 1050
3−1/2−Ton A/C Cooling 1225 0−1.0‡ 1155 1180 1200 1210 1220 1225 1225 1225 1225 1225
4−Ton A/C Cooling 1400 0−1.0‡ 1395 1400 1400 1400 1400 1400 1400 1390 1375 1355
5−Ton A/C Cooling 1750 0−1.0‡ 1740 1750 1750 1750 1735 1740 1735 1730 1715 1700
6−Ton A/C Cooling 2100 0−1.0 2075 2085 2090 2100 2100 2100 2090 2080 2055 2025
Maximum 2200 0−1.0 2180 2195 2200 2200 2200 2200 2185 2165 2140 2095
Air Delivery−CFM Notes
*Actual external static pressure (ESP) can be determined by using the fan laws (CFM 2 proportional to ESP); such as, a system with 1180 CFM at 0.5
ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low−heating airflow of 735 CFM at 0.19 ESP.
Efficiency airflow are shown in parenthesis. Efficiency is selected when the low−heat rise adjustment switch (SW1−3) is OFF and the comfort/effi-
ciency switch (SW1−4) is OFF.
Ductwork must be sized for high−heating CFM within the operational range of ESP.
Operation within the blank areas of the chart is not recommended because high−heat operation will be above 1.0 ESP.
***All airflow on 110 size furnace are 5% less on side return only installations.