20 | Assembly
7.3 Assembly with
adhesive pad
Only the adhesive pad supplied
by Hekatron may be used for the
assembly with adhesive pad.
CAUTION
The assembly with an adhesive pad
depends on the adhesion characteristics
of the surface of the ceiling in the
desired assembly position. If the surface
is unsuitable, the smoke alarm will not
permanently adhere to the ceiling.
f For the selection of a suitable
surface, please observe the
following table:
Adhesive pads may leave residues
after their removal.
f Clean the surface in the desired
assembly position.
f Remove the protective foil on one
side of the adhesive pad and attach
the pad to the base of the smoke
alarm. When doing so, observe the
recesses for the fastening pad.
f Remove the protective foil on the
other side, hold the base to the
desired assembly position and press
it rmly against the ceiling (for at
least 5 seconds).
i
Suitable Unsuitable
Smooth, level,
undamaged,
clean and free
from dust, grease
and solvents
Loose paint and
porous surfaces (e.g.
plaster, emulsion paint,
plywood, chip-boards
and bre boards)
1
In some versions, the adhesive pad is an accessory
which must be ordered separately.