JS07N·JS07·JS08·JS12·JS14
30
Operating Instruction
Dry Battery Filling and Charging In-
structions
1. Remove the battery vent caps and per-
manently remove the plastic seal from
the battery vent openings.
2. Fill each cell with battery acid (electro-
lyte) until the level is sufficient to cover
the plates. Do not fill to maximum level
until the battery charge cycle is complete.
Overfilling can cause the battery acid to
overflow during charging. Neutralize bat-
tery acid spills with baking soda and wa-
ter.
3. Install the battery vent caps.
4. Charge the battery.
5. Check the battery acid level when the
charging cycle is complete. Replenish
with distilled water to the bottom of the fill
tube. Do not overfill.
Fall protection
Personal fall protection equipment (PFPE) is
not required when operating this machine. If
PFPE is required by job site or employer
rules, the following shall apply:
All PFPE must comply with applicable govern-
mental regulations and must be inspected and
used in accordance with the manufacturer’s
instructions.
After every using:
1. Select a security place which can be a
sturdy surface, without obstacles and
avoiding heavy transport.
2. Lower the platform.
3. Turn off the machine and remove the
key to avoid unauthorized use.
4. Lock the wheels of the machine.