25
PRECAUTIONS FOR USING THE CARTRIDGE
• The cartridge is for single use only and must be replaced after each ination with
a new cartridge of the same reference.
• Use only Helite brand cartridges available from your dealer or on the helite.com
website.
• Gas cartridges are considered hazardous materials and should be kept out of
reach of children and used with care.
• Never plug in the cartridge until it is completely screwed into its slot.
• If rust stains or signs of deterioration appear on the cartridge, replace it immedia-
tely and contact your dealer or Helite at sav@helite.com.
• The cartridge should be stored at temperatures between 0°C (32°F) and 45°C
(113°F). It should be stored away from moisture and light.
• If the cartridge has been stored at temperatures below 0°C (32°F), we recommend
keeping it at ambient temperature for several minutes before using your airbag
vest to avoid malfunction of the airbag.
• Do not expose the cartridge for a long period of time to high temperatures (in full
sun in a car, near a radiator, etc.) near a surface or ammable objects.
• Do not hit the cartridge, do not drop it, do not cut or pierce it, and do not throw
it into re.
• Caution, the gas inside the cartridge is compressed to a very high pressure.
• Find more information about the annual verication of the cartridge on page 37,
its recycling on page 38 and its warranty on page 38.
4
SAS-TEC back protector level 2
It is integrated into the airbag vest and provides a big improvement in protection
(TURTLE Technology).
5
USB cable
It allows to recharge the battery of the airbag vest CDU electronic card (see page
31). Please note: only the USB cable is supplied, you will then have to connect it to
a standard USB charger (5 VDC).
6
SDU fork sensor (optional)
It detects abnormal movements of the motorcycle and communicates with the CDU
electronic card by radio frequency. It is installed under the fork of the motorcycle.
Under optimal conditions, the SDU fork sensor has an autonomy of about 5 years.
It is not rechargeable. We advise you to check its working condition at least once
a month. It is supplied with the SDU fork sensor. A magnet is provided to pair the
airbag vest with the SDU fork sensor (see page 28) and for regular checks. To learn
more about the SDU fork sensor and its conditions of use, please refer to its
dedicated user guide.