EasyManua.ls Logo

HELIX Compressor 9600 - Power Cable Connections

HELIX Compressor 9600
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3-14 P/N 8040540
C
HELIX TECHNOLOGY CORPORATION
-
TI C
RY
OG
EN
ICS
1. Connect the Supply and Return lines to the 9600 Compressor as
described in Connecting/Disconnecting Helium Flex Lines
within this section.
2. Connect the Gas Return Line to the customer supplied helium
manifold and then to the Gas Return connector on the Cryo-Torr
Cryopump.
3. Connect the Gas Supply Line to the customer supplied helium
manifold and then to the Gas Supply connector on the Cryo-Torr
Cryopump.
Power Cable Connections
1. Connect the Cryo-Torr power cable between the CRYOPUMP
ELECTRICAL OUTLET on the rear panel of the Compressor
and the CRYOPUMP ELECTRICAL INPUT on the Cryo-Torr
Interface as shown in Figures 3-8 or 3-9.
2. Connect the Cryo-Torr Power Cables between the CRYOPUMP 1,
2, or 3 connectors on the Cryo-Torr Interface and the respective
Cryo-Torr Cryopumps as shown in Figures 3-8 or 3-9.
3. Connect the User Remote cable to the Cryo-Torr Interface as shown
in Figures 3-8 or 3-9.
4. Connect the Remote cable between the Cryo-Torr Interface and the
Compressor as shown in Figures 3-8 or 3-9.
NOTE: Your installation may vary based upon the Cryo-Torr Cryopump
models used. Refer to Appendix A to consult your local
CTI-CRYOGENICS Customer Support Center for information on specific
compressor/cryopump applications.

Table of Contents