FM06-082A
SERVICE
MANUAL
MODEL 500
MODEL 561
44--HHeeaadd EElleeccttrriicc
PPrreessssuurree FFrryyeerrss

Table of Contents

Other manuals for Henny Penny 500

Questions and Answers

  • K
    Kelsey ComptonAug 18, 2025
    What to do if my Henny Penny 500 shows “E-4” “CPU TOO HOT”?
    • J
      Jennifer BushAug 18, 2025
      If the display shows “E-4”, the control board is getting too hot. First, turn the switch to the off position, then turn it back on. Check the louvers on each side of the unit for obstructions and inspect the cooling fan, if your fryer has one.
  • K
    Kevin BerryAug 20, 2025
    What to do if my Henny Penny 500 Fryer shows “E-5” “OIL TOO HOT”?
    • D
      Dawn JohnstonAug 20, 2025
      If the display shows “E-5”, the shortening is overheating. Turn the switch to the off position, then turn the switch back to on. This relates to the heating circuits.
  • R
    Rhonda IngramAug 22, 2025
    What to do if my Henny Penny 500 Fryer is not draining shortening?
    • E
      Eric BaileyAug 22, 2025
      If the shortening is not draining, push a cleaning rod through the open drain valve. The drain valve may be clogged.
  • J
    Joseph SparksAug 25, 2025
    Why is my Henny Penny 500 shortening not heating?
    • M
      Mark SmithAug 26, 2025
      If the shortening is not heating, make sure the gas control valve knob is turned to the on position. The gas valve knob may be in the off position.
  • K
    Kelly TaylorAug 27, 2025
    What to do if my Henny Penny Fryer is showing error “E-15” Drain valve open?
    • G
      gomezbrittanyAug 27, 2025
      Close the drain valve.
  • J
    Jessica BarkerAug 30, 2025
    What to do if my Henny Penny 500 Fryer pressure does not build?
    • Z
      Zachary HicksAug 30, 2025
      If the pressure does not build, place a full capacity of product in the frypot when using fresh shortening. There may not be enough product in the frypot.
  • S
    Sarah Cowan MDSep 1, 2025
    What to do if my Henny Penny 500 condensation line is clogged?
    • A
      Angela BrownSep 1, 2025
      Remove and clean the condensation line.
  • L
    Laura ArmstrongSep 4, 2025
    What to do if my Henny Penny Fryer pressure does not exhaust at end of cook cycle?
    • J
      James WareSep 4, 2025
      If the pressure is not exhausting, turn off the fryer and allow it to cool to release the pressure in the frypot. Have all lines, the solenoid, and the exhaust tank cleaned, as the solenoid or exhaust line may be clogged.
  • T
    thomaslawrenceSep 6, 2025
    What to do if my Henny Penny Fryer filter motor will not run?
    • M
      marcus94Sep 6, 2025
      If the filter motor will not run, reset the motor, as it may have overheated.
  • M
    Michael HarrisSep 9, 2025
    What to do if my Henny Penny Fryer operating pressure is too high?
    • E
      Edward GallowaySep 9, 2025
      If the operating pressure is too high, turn off the fryer and allow it to cool to release the pressure in the frypot. Clean the deadweight, as it may be clogged.

Summary

Chapter 1 Troubleshooting

Chapter 2 Maintenance Procedures

2.11 High Temperature Limit Control

Description, checkout, and replacement of the high temperature limit safety control.

2.12 Heating Elements

Description, checkout, and replacement procedures for heating elements.

2.13 Heating Contactors

Description, checkout, and replacement of primary and heat contactors.

2.16 Pressure Regulation and Exhaust System

Covers solenoid valve, deadweight valve, safety relief valve, and pressure gauge.

2.17 Filtering System Components

Information on filter rinse hose, valve, pump repair, and cover/pump removal.

2.19 Wiring Diagrams

Location and reference to wiring diagrams for various models.

Chapter 3 Parts Information

3.10 Parts and Illustrations

Illustrates components and lists associated part numbers and quantities.

Chapter 6 Programming Menu Options

T-14 Amps Calibration Procedure

Calibrates amp sensors to monitor heating element current.

Chapter 7 Wiring Diagrams

7.1 500 EF, 208-240 v, 50;60 Hz, 1 P (Before 04;01;06)

Wiring diagram for a specific model and configuration.

7.2 500 EF, 208-240 v, 50;60 Hz, 1 P (After 04;01;06)

Wiring diagram for a specific model and configuration.

7.12 500 EF, 208-240 v, 50;60 Hz, 1 P (Before 04;01;06)

Wiring diagram for a specific model and configuration.

7.21 500 SC EF, 208;240 v, 50;60 Hz, 3 P

Wiring diagram for a specific model and configuration.

Chapter 8 Annual Inspection Checklist

8.10 Inspect Solenoid and Deadweight Plumbing

Inspects plumbing for cleanliness and blockages, checks for leaks.

8.15 Inspect the High Limit Probe

Visually inspects the high limit probe bulb and capillary tube for damage.