Loading...
10
SPECIFICATIONS
Housing Material Impact resistant polymer composite
Environmental
Protection
IP 65 (Exceeds Nema 12/13)
Dimensions
Length: 10.4 in., 245 mm
Height: 6.3 in., 161 mm
Depth: 4.4 in., 90 mm
Weight 2,5 kg (5.5 lbs)
Antenna External, TNC socket
Voltage Supply 12 to 24 Vdc (-50% - +20%)
Decoding Multiple bit scanning, self-monitoring
Fuses 7.5 Amp. / 80 V car fuse
Frequency Range 419 MHz, 429 MHz, 434 MHz, 447 MHz, 458 MHz, 480 MHz, 868 MHz
Output
Intrinsically safe stop with double - FET, 1 safety valve (dump valve), 11 digital, 16
internal digital.
RF Unit Type CS synthesized with multiple frequencies
Typical Operating
Range
Up to 100 m (300 ft.)
Safety Address
20-bit (over 999,999 individual possibilities)
Address Module (ADMO)
Safety
Active and passive Stop function
Parity & Checksum
Temperature
Range
-11 to +158 degrees F (-20 to +70 degrees C)
Humidity Range 0 - 97% maximum non-condensing
Response Time Less than 100 msec.
Data Format 2400/4800 Baud, hamming distance 3.