3.5.1 Configuration File Edits
The Setup Host Communication screen will take you to the Edit Configuration Files screen. The
configuration files described in this section will enable DHCP TCP/IP host communications. See sections 3.2,
3.3, and 3.4 for instructions on how to start.
Select a file from the list the appropriate configuration file and click Edit File. If you need to clear the
selection, click Clear Selection.
While following these instructions edit the circled areas shown.
Note: In addition to these configuration file edits, you may be interested in changing the “hostname”. See
/mnt/flash/etc/conf.d/hostname for instructions on changing the host name.
3.5.1.1 /mnt/flash/TaskConfig/CommCfg
From the Edit Configuration Files screen, then edit the
/mnt/flash/TaskConfig/CommCfg configuration
file.
1. Select
/mnt/flash/TaskConfig/CommCfg from the list.
2. Click Edit File. The Edit File window will display.
3. Enter the appropriate configuration data, see the Pre-Installation Checklist – Ref #4, page 23
, for the
VertX controller to communicate to the host.
Example:
#
# commtask configuration parameters
# ------------------------------------------------------
# Connect to host on startup (1=>yes)
connect_on_start 1
# If contacted by a host, maintain connection without callback (1=>yes)
maintain_host_connection 0
# Call the host machine on this port
connection_port 4070
# Listen on this port for host connection requests
listen_port 4050
# If a connect attempt fails, wait this interval (~secs)
# before attempting to connect to the next host in CommHosts
reconnect_interval 15
# If no messages are received from the host within this interval (~min)
# then disconnect. (timeout = 0 => no timeout, continuous connection)
timeout 0
# Encrypt host communications (0=no, 1=yes)
use_encryption 0
# If a response to a host request is not received within this time (~secs),

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HID VertXHID V2000 and is the answer not in the manual?

HID VertXHID V2000 Specifications

General IconGeneral
Number of Doors2
Number of Readers2
Outputs4
Communication InterfaceEthernet, RS-485
Power Supply12-24 VDC
Operating Temperature0°C to 70°C
Humidity0% to 95% non-condensing
Weight0.45 kg
Inputs8 supervised inputs