What to do if HIDROCONTROL R-DRIVE pump is not connected?
- SShawn RossSep 23, 2025
If the HIDROCONTROL Adapter pump is not connected, check that the power output cable from the inverter is connected to the pump.
What to do if HIDROCONTROL R-DRIVE pump is not connected?
If the HIDROCONTROL Adapter pump is not connected, check that the power output cable from the inverter is connected to the pump.
What to do if my HIDROCONTROL Inverter pump runs continuously for too long?
If your HIDROCONTROL Inverter pump hasn't stopped in over 24 hours, as set in parameter 58, it likely indicates leaks. Locate and eliminate any leaks causing pressure loss and continuous pump operation, or adjust the time in parameter 58. You can also eliminate leaks from the extended menu, parameter 60.
What to do if HIDROCONTROL Inverter detects excessive current in the pump?
If the HIDROCONTROL Inverter detects excessive current in the pump: - Measure the output current using the 'output current' parameters and set the correct 'Max Corr. Motor' parameter. - Ensure the pump is used under the manufacturer's prescribed conditions and that there are no friction or rotor blockage issues.
What to do if my HIDROCONTROL Inverter detects a pressure sensor failure?
If your HIDROCONTROL Inverter detects a failure in the pressure sensor: - Verify that the pressure sensor is correctly connected. - Check that the value of the “Frecuencia Sensor presión” parameter is greater than 400. - If the problem persists, replace the pressure sensor.
What to do if HIDROCONTROL Inverter pump runs continuously?
If the HIDROCONTROL Inverter pump has been running continuously for the time set in parameter 40: - Verify the proper functioning of the flow valve. - Check for leaks in the system.
What to do if HIDROCONTROL R-DRIVE Adapter does not detect water?
If the HIDROCONTROL Adapter detects a lack of water, check for water presence. In the RDPW model, verify the check valve. In the RDPA model, verify the value of 'Dry Run Power'. Reset the correct pump priming function and check that the filter is not blocked.
What to do if HIDROCONTROL R-DRIVE pump runs continuously?
If the HIDROCONTROL Adapter detects that the pump has been running continuously for the time established in parameter 40, verify the proper functioning of the flow valve and check for leaks in the system.
How to fix HIDROCONTROL Adapter pump that has not stopped in 24 hours?
If the HIDROCONTROL Adapter detects that the pump has not stopped in more than 24 hours, it indicates the possible presence of leaks. Locate and eliminate any leaks that are causing pressure losses and continuously starting the pump, or change the time in parameter 58. You can also eliminate leaks from the extended menu par.60.
What to do if my HIDROCONTROL Inverter is off?
If the HIDROCONTROL Inverter is off and the pump control is deactivated, repeat the startup procedure, setting “System start” = ON.
What to do if HIDROCONTROL Inverter detects high voltage?
If the HIDROCONTROL Inverter detects a voltage that is too high, check the wiring system and set the values within the range prescribed for the R-DRIVE. The reset is automatic when the voltage returns to correct values.
Read manual, qualified personnel for installation, and use of non-original parts voids warranty.
Risk of personal injury and property damage from electrical shock.
Risk of damage to property or environment if not complied with.
Choosing the correct pump for optimal performance with R-DRIVE, considering head and capacity.
Using LCA for long connections and EMI filters for sensitive environments.
Guidance on hydraulic and electrical connections and system diagrams.
Configuring language, motor current, system pressure, and start for single pump.
Configuring Master/Slave for multi-pump systems, including network ID and motor settings.
Saving parameters to memory and exiting the setup process.
Verifying and setting the correct rotation direction for the electro-pump.
Information on manual usage, product overview, and available R-DRIVE models.
Detailed technical data for R-DRIVETT, R-DRIVEMT, and R-DRIVEMM models.
Electrical connection diagrams and safety precautions for different versions.
Features of expansion boards for MM/MT and TT models.
Configuring float switches and relays for system control and alarms.
Setting up and operating the booster mode for enhanced pressure control.
Connecting R-DRIVE units in Master/Slave mode with cable examples.
Sizing and calculating preload for expansion tanks to prevent water hammer.
Tips for installing taps, filters, check valves, and sensor placement warnings.
Schematic of a surface pump system with an air-cooled R-DRIVE.
Overview of parameters accessible via the maintenance menu for system adjustments.
Interpreting messages for system off, active, leakage, low voltage, and motor issues.
Diagnosing high voltage, short circuits, locked systems, and motor disconnection errors.
Troubleshooting float switch, water hammer, disconnected slaves, and standby faults.
Identifying multi-pump service outages, high temperature, and insufficient pressure faults.
Resolving 'No Water' errors and pressure sensor faults.
Setting password, frequency, language, network ID, and input/output parameters.
Configuring motor speed, restart attempts, perturbation, and protection parameters.
Setting PID coefficients, system response presets, and pressure sensor parameters.
Setting pump ON time, relay functions, booster pressure, and leak calculations.
Displaying fault counters, serial numbers, sector pressure, and software version.
| Brand | HIDROCONTROL |
|---|---|
| Model | R-DRIVE Series |
| Category | Adapter |
| Language | English |