Thermal Monocular User Manual
18
3. Press or to select , and press to enter the
configuration interface.
4. Press or to switch FFC mode.
Manual FFC: Hold in the live view to correct the non-
uniformity of display.
Auto FFC: The device performs FFC automatically according to
the set schedule when switching on the camera.
External: Cover the lens cover, then hold in the live view to
correct the non-uniformity of display.
Hold to save the settings and exit.
The countdown will start before the device performs FFC automatically.
3.13 Correct Defective Pixel
The device can correct the defective pixels on the screen which are not
performed as expected.
Steps
Hold to show the menu.
Go to Advanced Settings, and select Function Settings.
Press or to select , and press to enter DPC
configuration interface.
Press to select X or Y Axis. If you select X axis, the cursor moves
left and right; if you select Y axis, the cursor moves up and down.
Press or to set the coordinates until the cursor reaches the
defective pixel.
Press twice to correct the dead pixel.
Hold to save the settings and exit.