SC5000 Series Smart Camera Quick Start Guide
18
Input Signal
Ground
Device Power
PWR
Device Power Ground
NPN
Device
NPN Device Power
NPN Power Ground
Signal Line
VCC
GND of PWR
Opto-Isolated Input
GND of VCC
Figure 7-6 Input Signal Connecting to NPN Device without Pull-Up Resistor
If the VCC of NPN device is 12 VDC or 24 VDC and 1 pull-up resistor is used, its wiring is as
follows.
Opto-Isolated
Input
Device Power
PWR
Device Power Ground
NPN
Device
NPN Device Power
NPN Power Ground
Signal Line
VCC
GND of PWR
Input Signal Ground
GND of VCC
Figure 7-7 Input Signal Connecting to NPN Device with Pull-Up Resistor