    Brittany SimmonsAug 11, 2025
    Why is the live view black on my HikRobot MV-CL021-40GM Digital Camera?
    • J
      Justin AlvarezAug 11, 2025
      The live view might appear black because the lens aperture is set too large, or the camera’s exposure value is too small. You should reduce the lens aperture value and increase the camera’s exposure value, or enable auto exposure mode.
  • S
    Sarah HallAug 17, 2025
    What to do if I get a camera connection error with my HikRobot MV-CL021-40GM?
    • C
      Christopher WilliamsAug 17, 2025
      A camera connection error can occur if the camera and the client software are not on the same network segment. To fix this, use the MVS IP Configurator tool to find the camera and edit its IP address.
  • Y
    ycookAug 23, 2025
    How to fix 'no camera found' error for HikRobot Digital Camera in MVS client software?
    • A
      Amanda PerkinsAug 23, 2025
      If the MVS client software can't find the camera, it might not be started up normally, or there may be a network cable connection error. Check the camera power wiring (observe the indicator) and the network connection.
  • M
    Misty GibsonAug 28, 2025
    What to do if my HikRobot Digital Camera live view is normal but it cannot be triggered?
    • W
      william07Aug 29, 2025
      If the live view is normal, but the camera cannot be triggered, the trigger mode might not be enabled, the trigger source could be incorrect, or the trigger wiring may be faulty. Check whether the trigger mode is enabled and the selected trigger source is correct. Also, check the trigger wiring.
  • V
    vgloverSep 3, 2025
    Why can't I set Line Mode to Strobe on my HikRobot Digital Camera?
    • G
      Gina RossSep 3, 2025
      If a bi-directional configurable line signal is selected as Line Selector, and Line Mode is currently set to Input, you cannot set Line Mode to Strobe because the bi-directional configurable line signal is selected as the trigger source in one of the line trigger/frame trigger/shaft encoder control/ frequency converter control settings. To resolve this, set other line signals as the trigger source in all line trigger/frame trigger/shaft encoder control/ frequency converter control settings.

HikRobot MV-CL021-40GM Specifications

General IconGeneral
Sensor Size1/1.8"
Frame Rate40 fps
InterfaceGigE
Pixel Bit Depth8/10/12 bit
Sensor TypeCMOS
Lens MountC-Mount
Shutter TypeGlobal Shutter
Operating Temperature0°C to 50°C
Power Supply12 VDC
Dimensions29 mm x 29 mm x 42 mm