GigE Line Scan Camera·User Manual
31
If the frame trigger is enabled, the relation between trigger source and trigger related
parameters is shown below.
Table 7-4 Trigger Source and Trigger Related Parameters
Trigger Source
Parameters
Software Trigger
Hardware Trigger
Frequency
Converter Control
Free Trigger
Acquisition Burst Frame
Count
Trigger Activation
×
Trigger Delay
Frame Trigger Cache
Trigger Debouncer
×
If the line trigger is enabled, the relation between trigger source and trigger related
parameters is shown below.
Table 7-5 Trigger Source and Trigger Related Parameters
Trigger Source
Parameters
Hardware Trigger
Shaft Encoder
Control
Frequency
Converter Control
Free Trigger
Trigger Activation
Trigger Delay
Line Trigger Cache
Trigger Debouncer
×
×
7.6.1 Acquisition Burst Frame Count
If the camera enables the frame trigger, you can set the acquisition burst frame count. Click
Acquisition Control > Acquisition Burst Frame Count, and enter Acquisition Burst Frame Count
according to actual demands. Its range is from 1 to 1023.