Note
The function varies according to different camera models.
1)Click .
2)Check Enable Offsite.
3)Set the offsite pre-alarm/alarm and follow step 4~5 to adjust the pre-alarm/alarm
temperature and arming schedule during working hours.
Note
The same parameters and linkage method apply to the two kinds of pre-alarm/alarm,
only the threshold temperature and arming schedule vary.
Offsite Pre-Alarm Temperature
When the temperature of target exceeds the Offsite Pre-Alarm Temperature during
the Offsite Arming Schedule, and this status lasts not shorter than the Filtering Time,
the pre-alarm is triggered.
Offsite Alarm Temperature
When the temperature of target exceeds the Offsite Alarm Temperature during the
Offsite Arming Schedule, and this status lasts not shorter than the Filtering Time, the
alarm is triggered.
Offsite Arming Schedule
Click and drag the time bar to select the arming off-hours for offsite pre-alarm and
alarm.
9.
Click Save.
Click Live View, and select thermal channel to view the temperature and rules
information on live view.
Point Thermography
Congure the temperature measurement rule and click any point in live view to monitor the
temperature.
Steps
1.
Click in the live view and a cross cursor shows on the interface.
2.
Drag the cross cursor to desired position.
Go to Live View interface to view the temperature and rule of the point in thermal
channel.
Thermal & Optical Bi-spectrum Network Camera User Manual