Calibrate the Camera
Steps
1.
Go to Conguration > Perimeter Protection > Camera Calibration or Conguration >
Perimeter Protection > Advanced Conguration .
Note
The path varies according to different camera models.
2.
Check Camera Calibration.
3.
Select Calibration Mode.
-
For Self-Learning Calibration, see
Self-Learning Calibration
.
-
For Traditional Calibration, see
Calibrate Automatically
and
Calibrate Manually
.
Note
The function varies according to different camera models. If Calibration Mode is not
supported, see
Calibrate Automatically
and
Calibrate Manually
.
Self-Learning Calibration
The self- learning calibration allows a camera calibration based on the automatic analysis
of people height data.
Steps
1.
Select Filter Level. The higher the level is, the more easily the alarm can be triggered.
2.
Check Camera Calibration. The device will automatically record and analyze the height
range of people at different positions,
ltering out the target out of the range.
3.
The calibration area is divided into 20 rows. There needs to be a person walking back
and forth twice in the white area (uncalibrated) until all the lines turn to green
(calibrated). You can pause the calibration process or recalibrate.
Thermal & Optical Bi-spectrum Network Camera User Manual
70