User Manual of Thermal Bi-spectrum Network Speed dome
© Hikvision
61
information in live view.
Add Original Data on Capture: Check the checkbox to add original data on capture.
Add Original Data on Stream: Check the checkbox to add original data on stream.
Data Refresh Interval: Select the data refresh interval from 1s to 5s.
Unit: Display temperature with Degree Celsius C)/Degree Fahrenheit F)/Degree Kelvin
(K.
Temperature Range: Set the temperature range.
Version: View the version of current algorithm.
3. Clcik Save to save the settings .
5.4.2 Temperature Measurement and Alarm
Purpose:
This function is used for measuring the temperature of detected spot and the device compares
temperature of selected regions and alarms.
Steps:
Normal Mode
1. Enter Configuration > Temperature Measurement > Advanced Settings.
2. Select the temperature measurement and alarm configuration as Normal.
3. Configure the parameters.
Figure 5-26 Temperature Measurement Configuration
Emissivity: Set the emissivity of your target. Note: The emissivity of each object is
different.
Distance (m): The straight-line distance between the target and the device.