Network Video Recorder User Manual
55
The PoE is enabled with the short network cable mode (OFF) by default.
The bandwidth of IP camera connected to the PoE via long network cable (100 - 300 meters)
cannot exceed 6 MP.
The allowed max. long network cable may be less than 300 meters depending on different
IP camera models and cable materials.
When the transmission distance reaches 100 to 250 meters, you must use the CAT5E or
CAT6 network cable to connect with the PoE interface.
When the transmission distance reaches 250 to 300 meters, you must use the CAT6
network cable to connect with the PoE interface.
Refer to the Appendix 16.3 List of IP Cameras Connected to PoE by Long Network Cable
(100 - 300 m) for the list of IP cameras.
You can check the connecting status and power information of PoE channel on the interface.
Step 3 Click Back to finish the settings.

Table of Contents

Other manuals for HIKVISION DS-7608NI-Q1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7608NI-Q1 and is the answer not in the manual?

HIKVISION DS-7608NI-Q1 Specifications

General IconGeneral
Two-way talkYes
Input bandwidth80 Mbit/s
Number of users64 user(s)
Maximum resolution4096 x 2160 pixels
Video input channels8 channels
Supported resolutions4096 x 2160, 3840 x 2160, 2560 x 1440, 1920 x 1080, 1600 x 1200, 1280 x 1024, 1280 x 720
Audio formats supportedG.711 A-law, G.711 μ-law, G.726
Video formats supportedH.264, H.264+, H.265, H.265+, MPEG4
Wi-FiNo
HDD capacity- GB
HDD interfaceSATA
Maximum storage capacity8 TB
Number of HDDs installed0
Number of HDDs supported1
USB 2.0 ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Supported network protocolsTCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, NFS, iSCSI, ISUP, UPnP, HTTP, HTTPS
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Output voltage12 V
Power consumption (typical)10 W
CertificationFCC Part 15 Subpart B, ANSI C63.4-2014 CE EN 55032: 2015, EN 61000-3-2, EN 61000-3-3, EN 50130-4, EN 55035:
Product colorBlack
Rack capacity1U
Weight and Dimensions IconWeight and Dimensions
Depth240 mm
Width320 mm
Height48 mm
Weight1000 g

Related product manuals