3.2.1 Descripon of Cable
The descripon of 10 cables is shown below.
Table 3-2 Descripon of Cable
Color Descripon
Orange Wiegand ERR (Available for Wiegand Protocol)
Brown Wiegand OK (Available for Wiegand Protocol)
White Wiegand W1 (Available for Wiegand Protocol)
Green Wiegand W0 (Available for Wiegand Protocol)
Blue RS-485-
Yellow RS-485+
Red PWR (+12 VDC)
Black GND
Gray TAMPER Control
Purple Beep Control (Available for Wiegand Protocol)
3.2.2 Set RS-485 Communicaon Mode
Steps
1. Set the DIP switch of No. 6 as 0.
2. Set the DIP switch of No. 1 ~ 5 for RS-485 address and reading card mode. For details, refers to
DIP Switch
Descripon .
3. Wire the cable between controller and card reader as shown below.
DS-K1108A Series Card Reader User Manual