Specificaon
10
Operaon Cauon and Device Maintenance
- All the electronic operaon should be strictly compliance with the electrical safety regulaons, fire prevenon regulaons and other related
regulaons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service
center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specificaon of the device for the detailed operaon temperature), cold, dusty or
damp locaons, and do not expose it to high electromagnec radiaon.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or radiator is forbidden (ignorance can cause fire
danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfuncon however), and
affecng the endurance of sensor at the same me.
- Improper use or replacement of the baery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of
used baeries according to the instrucons provided by the baery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situaon.
Detecon gap According to the magnet detecon performance table
One reed switch Yes
External inputs 2
Shock detecon Yes
Tilt detecon Up to 25°
Tamper protecon Front & Back
LED indicator Green(MC), Orange(lt), Red(shock), Blue(alarm)
Encapsulated plasc Yes
Input opons Normal and Fast Sensivity with Pulse Count
Programmable pulse count Yes
Fast input sensivity 1ms
Normal input sensivity 30
0ms
Operang temperature
-10 °C to 55 °C (14 °F to 131 °F)
-10 °C to 40 °C (14 °F to 104 °F) Cerfied
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operang humidity 10% to 90%
Dimension (H × W × D)
Sensor: 22.5mm × 103mm × 23.2mm
Magnet: 13mm × 34.4mm × 11.4mm
Weight 60 g
Wireless technology Tri-X Wireless Technology
Programming method Advanced Wireless Link
LED indicator On/Off
Shock sensivity adjustment High/Normal/Low
Tilt 5° to 25°
External Input 1 NC/NO, Roller Shuer (RS), Tamper
External Input 2 NC/NO, Roller Shuer (RS), Tamper
RS Pulse Count 2 to 30 Pulses
RS Pulse Count Timeout 10 to 60s
Environment temperature indicator Yes
2-way wireless communicaon Yes
Transmiss
ion frequency 868MHz
Frequency hopping Mulchannel transmisson
Transmission encrypon AES-128 encrypon
Signal strength indicators Yes
RF range 1.6 km (open area)
Enrolling methods Power up, Remote ID, QR code
Baery CR123A x 1 (included)
Standard baery life 3 years