7 Specification
6 Operation Caution and Device Maintenance
- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention
regulations and other related regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment
damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then
please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment
damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation
temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden
(ignorance can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not
a malfunction however), and affecting the endurance of sensor at the same time.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or
equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufactur-
er.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situation.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
5 Formatting
Hold the tamper switch for 8 s and power the device on at the same time. The red LED flashes 3 times when the formatting
operation is completed.
6
Detection range
12m, 85.9°
Detection speed 0.3 ~ 2 m/s
Auto sensitivity Yes
Pet immunity
Up to 30Kg (Height<40cm)
Digital temperature compensation Yes
Technology Digital microprocessor based
Sealed optics Yes
Creep zone protection Yes
Direct light filter 6500lux
Sensor Omnidirectional electret microphone
Detection range 8m radius, 120°
Glass type Float, Plate, Tempered, Wired, Laminated Leaded, Double glazing
Glass thickness 2.4mm to 6.4mm
Glass size 0.3m x 0.3m to 3m x 3m
Sensitivity Low (1 m), medium (4m), and high (8 m)
Tamper protection Front & Back
LED indicator Green(PIR), Red(BG), Blue(alarm)
Encapsulated plastic Yes
Operating temperature
-10 °C to 55 °C (14 °F to 131 °F)
-10 °C to 40 °C (14 °F to 104 °F) Certified
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity 10% to 90%
Installation height 1.8 to 2.4m
Dimension (W × H × D) 65.5mm × 103mm × 48.5mm
Weight 134 g
Bracket Optional wall & ceiling accessory
Wireless technology Tri-X Wireless Technology
Environment temperature Indicator Yes
2-way wireless communication Yes
Transmission frequency 868MHz
Frequency hopping Multichannel transmisstion
Transmission encryption AES-128 encryption
Signal strength indicators Yes
RF range 1.6Km (free space)
Enrolling methods Power up, Remote ID, QR code
Battery CR123A x 2 (included)
Standard battery life 5 years
Glass Break Specification