5. Select a zone type. 
Instant Zone   
This Zone type will immediately trigger an alarm event when armed.   
Delay Zone   
Exit Delay: Exit Delay provides you time to leave through the defense area without alarm.   
Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system 
without alarm. 
The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in 
entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via 
operating keyboard for users.   
Note 
  You can set 2 different time durations in System Options → Schedule & Timer. 
  Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1. 
  You can set Stay Arm Delay Time for the delay zone. 
 
 
Panic Zone   
The zone activates all the time. It is usually used in the sites equipped with panic button, 
smoke detector and glass-break detector. 
Follow Zone 
The zone acts as delayed zone when it detects triggering event during system Entry Delay, 
while it acts as instant zone otherwise. 
Keyswitch Zone   
The linked area will arm after being triggered, and disarm after being restored. In the case of 
the tampering alarm, the arming and disarming operation will not be triggered. 
Note 
Two trigger types (by trigger times and by zone status) can be selected for the zone. If the zone 
status type is selected, set the trigger operation (trigger arming/disarming). 
 
Disabled Zone   
Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors. 
24-Hour Zone 
The zone activates all the time with sound/siren output when alarm occurs. It is usually used 
in fire hazardous areas equipped with smoke detectors and temperature sensors. 
Timeout Zone 
The zone activates all the time. The zone type is used to monitor and report the "ACTIVE" 
status of a zone, but it will only report and alarm this status after the programmed time has 
expired. (1 to 599) Seconds. It can be used in places equipped with magnetic contacts that