6.3 Switching between forward (clockwise) and reverse rotation
(counter-clockwise) 2
An interlock prevents switching while the motor is running. The control
switch is locked when the forward/reverse switch is in the middle
position (switch-on interlock).
1. Operate the forward/reverse switch.
The switch-on interlock is active.
2. Operate the forward/reverse switch.
The direction of rotation is set as desired.
6.4 Switching on and off
1. Press the control switch.
The power tool starts.
Speed can be controlled steplessly right up to maximum by varying
how far the control switch is pressed in.
2. Release the control switch.
The power tool switches off.
6.5 Screwdriving
1. Set the torque. page 11
2. Set the direction of rotation to forward (clockwise) or reverse (counter-
clockwise). page 12
3. Press the control switch. page 12
6.6 Drilling
1.
Set the torque setting ring to the symbol.
2. Set the direction of rotation to forward (clockwise). page 12
3. Press the control switch. page 12
7 Care and maintenance
WARNING
Risk of injury with battery inserted !
Always remove the battery before carrying out care and maintenance
tasks!
Care and maintenance of the tool
Carefully remove stubborn dirt.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning
agents containing silicone as these can attack the plastic parts.