5 Preparations at the workplace
CAUTION
Risk of injury by inadvertent starting!
Before inserting the battery, make sure that the product is switched off.
Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1 Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery.
5.2 Removing the saw blade
1. Remove the battery. page 10
2. Engage the transport lock.
3. Turn the chuck locking sleeve counterclockwise and hold it in this position.
4. Pull the blade forward out of the chuck.
5. Release the locking sleeve and allow it to move back to its original position.
5.3 Inserting the saw blade
Use only saw blades with a 1/2" connection end.
1. Remove the battery. page 10
Printed: 07.01.2019 | Doc-Nr: PUB / 5470139 / 000 / 00

Other manuals for Hilti SR 2-A12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti SR 2-A12 and is the answer not in the manual?

Hilti SR 2-A12 Specifications

General IconGeneral
Voltage12 V
Weight1.2 kg
Tool typeCordless reciprocating saw
Battery TypeLi-ion
Blade Length150 mm
Stroke rate3000 strokes/min