EasyManua.ls Logo

Hioki 3286-20 - Specifications of Power Factor and Phase Angle Measurements 1Φ PF Meter and 3Φ PF Meter

Hioki 3286-20
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
―――――――――――――――――――――――――――
Chapter 3 Specifications
――――――――――――――――――――――――
Measurement
conditions
Singe phase/balanced three phases,
50/60 Hz, sine wave
Measurement range
Effective measurement current range:
1 A to 1000 A
Effective measurement voltage range:
80 V to 600 V
Phase angle measurement φ
Method of
measurement
Measurement range
Obtained from phase detection circuit.
Measurement
Mode
Resolution Measurement Range Accuracy
φ
0.1 LEAD 90 to 0 to LAG 90 3
Power factor measurement λ
Method of
measurement
Measurement range
Obtained by calculation from phase
angles.
Measurement
Mode
Resolution Measurement Range Accuracy*
cosφ 0.001 LEAD 0 to 1 to LAG 0 3 2dgt.
* Calculating error of 2 dgt. is added to phase angle measurement error.
Reactive factor measurement
Method of
measurement
Measurement range
Obtained by calculation from phase
angles.
Measurement
Mode
Resolution Measurement Range Accuracy*
sinφ 0.001 LEAD 0 to 1 to LAG 0 3 2dgt.
* Calculating error of 2 dgt. is added to phase angle measurement error.
3.1.4 Specifications of Power Factor and Phase
Angle Measurements 1φ PF Meter and 3φ
PF Meter