EasyManua.ls Logo

Hioki CM4371 - Measurement Categories

Hioki CM4371
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Safety Notes
Measurement categories
This instrument conforms to the safety requirements for CAT III 1000 V, CAT IV 600 V
measuring instruments.
T
Outlet
Internal wiring
Distribution panel
Service entrance
Service drop
CAT IV
(≤600 V)
Power meter
CAT III
(≤1000 V)
Fixed installation
CAT II
(≤1000 V)