33
Signal contact (optional)
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires connected by tightening the terminal screws.
2.4.2 Wiring the digital input (optional)
Remove the power connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires connected by tightening the terminal screws.
2.5 Operating the device
Note: The torque for tightening the working voltage terminal block on the
device is 4.5 lb-in (0.51 Nm).
The torque for tightening the terminal block on the digital input of the device
is 3 lb-in (0.34 Nm).
Mount the terminal block for the operating voltage and the signal contact
using screws.
Optional: Mount the terminal block for the digital input by screwing.
Enable the working voltage.
Pin Signal, terminal Function
1 DI (+) Signal input
2DI () Reference potential
Table 10: Pin assignment: 2 pin, screwable terminal block (on the left), connection
to the device (to the right)