EMC and immunity
Note: You will find detailed information on the certificates and declarations applying to your device in a separate
overview.
See table 3 on page 21.
Stability Standard
applications
Navy applications Railway
applications
Substation
applications
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
0.14 in. (3.5 mm)
amplitude
2 Hz ... 13.2 Hz
with
0.04 in. (1 mm)
amplitude
2 Hz ... 9 Hz with
0.12 in. (3 mm)
amplitude
————
8.4 Hz ... 150 Hz
with 0.04 oz (1 g)
13.2 Hz ... 100 Hz
with 0.03 oz (0.7 g)
9 Hz ... 200 Hz
with 0.04 oz (1 g)
————
200 Hz ... 500 Hz
with 0.05 oz (1.5 g)
IEC 60068-2-27, test Ea Shock 0.53 oz (15 g) at
11 ms
0.53oz (10g) at
11 ms
EMC interference
emission
Standard
applications
Navy applications Railway
applications
(trackside)
Substation
applications
Radiated emission
EN 55022 Class A Class A Class A Class A
GL Guidelines EMC 1
FCC 47 CFR Part 15 Class A Class A Class A Class A
EN 61000-6-4 Fulfilled Fulfilled Fulfilled Fulfilled
Conducted emission
EN 55022 AC and DC supply connections Class A Class A Class A Class A