Installation GREYHOUND Switch
Release
01
04/2016
3 Making basic settings
Note: Two or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the HiDiscovery or
Industrial HiVision application
a
Configuration via BOOTP
a
Configuration via DHCP
a
Configuration via DHCP Option 82
a
AutoConfiguration Adapter
Default settings
IP address: The device looks for the IP address using DHCP
a
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9,600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s, full duplex
All other ports: autonegotiation
Out-of-band management port:
Default IP address: 192.168.1.1 / 255.255.255.0