EasyManua.ls Logo

Hirschmann GREYHOUND GRS1042 - Technical Data; General Device Specifications and Dimensions

Hirschmann GREYHOUND GRS1042
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
Installation GREYHOUND Switch
Release
01
04/2016
7 Technical data
7.1 General technical data
7.1.1 Basic device
Dimensions
W × H × D
See “Dimension drawings” on page 62.
Weight 7.93 lb (3.6 kg)
Power supply
Supply voltage
with characteristic
value L
Nominal voltage DC 24 V ... 48 V
48 V... 54 V
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
6.3 A
slow blow
Connection type 2-pin terminal block
Power supply
Supply voltage
with characteristic
value H
Nominal voltage AC 110 V ... 240 V, 50 Hz ... 60 Hz
Nominal voltage DC 60 V ... 250 V
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
2.5 A
slow blow
Connection type 3-pin terminal block
Signal contact Nominal value for AC I
max
=2A at U
max
=230V
Nominal value for DC I
max
=2A at U
max
=30V
I
max
=0.2 A at U
max
= 125 V
I
max
=0.1A at U
max
= 250 V
Climatic conditions
during operation
Ambient air temperature
a
Standard
up to 6560 FASL
(2000 m ü. NN)
over 6562 FASL
(2000 m)
+32 °F ... +140 °F
(0 °C ... +60 °C)
+32 °F to +122 °F
(0 °C ... +50 °C)
Extended
b
,
c
up to 6560 FASL
(2000 m ü. NN)
over 6562 FASL
(2000 m)
40 °F ... +158 °F
(40 °C ... +70 °C)
40 °F ... +140 °F
(40 °C ... +60 °C)
Extended with
conformal coating
b,c
over 6562 FASL
(2000 m)
over 6562 FASL
(2000 m)
40 °F ... +158 °F
(40 °C ... +70 °C)
40 °F ... +140 °F
(40 °C ... +60 °C)
Humidity 5 % ... 95 % (non-condensing)
Air pressure minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (1312 ft; 400 m)
Climatic conditions
during storage
Ambient temperature 40 °F ... +185 °F
(40 °C ... +85 °C)
Humidity 5 % ... 95 % (non-condensing)
Air pressure minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (1312 ft; 400 m)

Table of Contents