Error Code Error Cause Elimination
E26
Upper limit value in
measuring channel
"middle section" ex-
ceeded
• refer to E16 • refer to E16
E17
Fallen below lower
limit value for the
measuring channel
"telescopic jib".
• Angle sensor defective.
• Electronic part in the measur-
ing channel defective.
• Replace angle sensor.
• Replace LMI board.
E27
Upper limit value in
measuring channel
"telescopic jib" ex-
ceeded
• refer to E17 • refer to E17
E19
Reference and/or
supply voltage defec-
tive
• The supply voltage is falsified
by one of the sensors (DAV,
LWG)
• Check the voltages on the LMI
main board (AGND = MP0).
Check sensors, plugs and ca-
ble, replace, if need be.
• Electronic component is defec-
tive
• Replace LMI board