FULLY RETRACT
MAINBOOM XX.X ft
OK
EXIT
Displayed length indication
13.3.2
Length Sensor Calibration Procedure
After selecting ‘LEN’ in steps 1 through 4 at the beginning of this section complete the following pro-
cedure.
Fully retract the main boom.
Note: the displayed length indication
is noted by XX.X in following steps.
Verify the boom retracted boom length is correct. If incorrect, adjust length pot in cable reel define in
the Cable Reel LWG308/0001 Adjustment Procedure.
Press the ‘OK’ button.
Fully extend the main boom.
Press the ‘OK’ button.
After ‘OK’ the system request the length sensor calibration be saved.
Use the ‘UP’ and ‘DOWN” arrow buttons to select ‘YES’, which should be flashing then press ‘OK’ to
confirm calibration.
Press EXIT to leave calibration or select the ‘CALIBRATE SENSORS’ to calibrate another sensor.
FULLY EXTEND
MAINBOOM XX.X ft
OK
EXIT
SAVE CALIBRATION ?
YES
NO