5.3.2 Error Codes for the Analog Inputs
If it exceeds these limits, the following errors are triggered:
(NOTE: the upper limit follows the lower limit error, i.e. 11 and 21, 12 and 22, 13 and 23…)
Error Code Error Cause Elimination
E11
Fallen below limit for
the measuring chan-
nel "Length telescopic
boom".
Length sensor pot defective.
Electronic board in the meas-
uring channel defective.
Replace length sensor poten-
tiometer.
Replace LMI board.
E21
Upper limit value for
measuring channel
"length telescopic
boom" exceeded.
Length sensor pot defective.
Electronic part in the measur-
ing channel defective.
Replace length sensor poten-
tiometer.
Replace LMI board.
E12
Fallen below the lower
limit value in the
measuring channel
"pressure piston side"
Cable between the central unit
and pressure transducers de-
fective or water inside the
plugs
Check cable as well as plugs,
replace, if need be.
Pressure transducer is defecti-
ve.
Replace pressure transducer
Electronic component in the
measuring channel is defec-
tive.
Replace LMI main board or
processor board.
E22
Upper limit value in
measuring channel
"pressure piston side"
has been exceeded
refer to E12
refer to E12
E13
Fallen below lower
limit value in the
measuring channel
"pressure rod side"
refer to E12 refer to E12
E23
Upper limit value in
measuring channel
"pressure rod side"
has been exceeded.
refer to E12
refer to E12
E15
Fallen below lower
limit value for the
measuring channel
"angle main boom".
Angle sensor defective.
Electronic part in the measur-
ing channel defective.
Replace angle sensor.
Replace LMI board.
E25
Upper limit value in
measuring channel
"angle main boom"
exceeded
refer to E15 refer to E15
E16
Fallen below lower
limit value for the
measuring channel
"middle section".
Angle sensor defective.
Electronic part in the measur-
ing channel defective.
Replace angle sensor.
Replace LMI board.