Error Code Error Cause Elimination
E85 Error in the radius
determination
The computed radius is too small
(negative deflection)
Check the programming in
the data EPROM.
E91 No data transmission
form the console to
the central unit
24 V supply of the console is inter-
rupted
Check 24 V at terminal X1
of the console electronics
Interruption or accidental ground in
the line between console electron-
ics and central unit
Check the connection con-
sole electronics - central
unit. In case of an acciden-
tal ground, the transmitter
module of the console elec-
tronics might be damaged.
Transmitter/receiver module is
defective
Exchange console electron-
ics or LMI main board resp.
E92 Error in the data
transmission from
console to central unit
Loose connection in the line be-
tween console electronics and
central unit
Transmitter/receiver module is
defective
Check the connection be-
tween console electronics
and central unit
Exchange console electron-
ics or LMI main board resp.
E93 Error in the data
transmission from the
central unit to the
console
refer to E92 refer to E92
E94
No data transmission
from the central unit
to the console
Interruption or accidental ground in
the cable between central unit and
console
Check wiring to the console
(in case of accidental
ground, replace console
electronics, too).
5 V supply of the computer in the
central unit is missing
Check connection to the
power unit
5 V supply is too low Exchange the LMI main
board
Transmitter/receiver module is
defective
Replace console electronics
or LMI main board
Computer module is defective Replace processor board.
Electro-magnetic interferences
(e.g. when switching contactors or
valves)
Eliminate the source of in-
terferences by inverse di-
odes or varistors.
E95
Error in the console
EPROM
The console EPROM is defective. Replace the console
EPROM
E96
Error in the internal
RAM of the console.
The CPU of the console is defec-
tive.
The console main board is defec-
tive.
Replace the CPU of the
console
Replace the console main
board.