Manual
MH-083 Ecomaster Comfort user manual
17/17
MESSAGE
DESCRIPTION
23
PCHN
Short or Open circuit in the passenger's channel sensor
24
WTR
Short or Open circuit in the water sensor (passenger)
25
CMP
Short circuit at compressor output (passenger)
26
FP
Short circuit at recirculation pump output (passenger)
27
PV2
Short circuit at ON/OFF evaporator output speed 2(passenger)
28
PV1
Short circuit at ON/OFF evaporator output speed 1(passenger)
29
PS1
Short circuit at stair heater blower output speed 1 (passenger)
30
PS2
Short circuit at stair heater blower output speed 2 (passenger)
31
C1
Short circuit at ON/OFF condensor output (passenger)
32
PV3
Short circuit at ON/OFF evaporator output speed 3(passenger)
33
PRV
Short circuit in the roof valve output (passengers)
34
PHV
Short circuit in the floor valve output (passenger)
35
PRC
Short circuit at passenger recirculation flap output (passenger)
36
RB
Short circuit at right evaporator fans output (passengers)
37
LB
Short circuit at left evaporator fans output (passengers)
38
CB
Short circuit at condensor fans output (passenger)
39
PRVN
The roof valve was previously detected but now it is not detected (passenger)
40
PHVN
The floor valve was previously detected but now it is not detected (passenger)
41
FPN
The recirculation pump was previously detected but now it is not detected (passenger)
42
RPRV
The return of the roof valve is missing (passenger)
43
RPHV
The return of the floor valve missing (passenger)
44
MDFV
Motorised defogger valve without return position
45
MDHV
Motorised additional heater valve without return position
46
MPRV
Motorised roof valve without return position
47
MPHV
Motorised floor valve without return position
Warning codes:
Message
Description
1
POT?
Inconsistency between POT selected and configuration detected
2
RAD
Short or Open in radiation sensor (driver)
3
DFBN
No charge in defroster fans PWM (passengers)
4
RH
Short or Open in humidity sensor (passengers)
5
PRBN
No charge in right evaporator fans PWM (passengers)
6
PLBN
No charge in left evaporator fans PWM (passengers)
7
CBN
No charge in condenser fans PWM (passengers)
8
LPD
Low pressure error (Driver zone)
9
HPD
High pressure error (Driver zone)
10
LPP
Low pressure error (Passenger zone)
11
HPP
High pressure error (Passenger zone)