8
CP-WX11000 ( P6WX )
4-5
White balance adjustment
 (visual inspection)
Preparations
1.  Perform these adjustments after the adjust-
ments described in Section 4-5.
2.  Reset gamma correction before adjustment.
Place the cursor on [GAMMA] in the FACTORY 
MENU, press the [RESET] key and select RESET.
Adjustment procedure
1. First, adjust the G colour.
2.
Select GAMMA, SUB-CNT, and G: in the FACTORY 
MENU. If the background is white solid, press the 
[ENTER] key on the Remote control transmitter to 
change to [G] monochrome in the 33-tone greyscale.
3.  Adjust GAMMA, SUB-CNT, and G: in the FAC-
TORY MENU so that brightness of 33 steps is 
best.
4.  Don’t adjust GAMMA, SUB-BRT, and G: in the 
FACTORY MENU because we want to keep the 
best contrast ratio.
5. Then adjust colours R and B.
6.
Select GAMMA, SUB-CNT and G: in the FACTORY 
MENU. If the background is white solid, press the 
[ENTER] key on the remote control to change to [W] 
monochrome in the 33-tone greyscale.
7.  Adjust GAMMA, SUB-BRT, R: and B: in the 
FACTORY MENU so that low-brightness white 
balance is best.
8.  Adjust GAMMA, SUB-CNT, R: and B: in the 
FACTORY MENU so that middle-brightness 
white balance is best.
9. Repeat steps 7 to 8 above and adjust so that 
brightness white balance of 33 steps is best.